Loader Image

Power, Grounding, Bonding, And Audio For Ham Ra... May 2026

is the act of connecting all conductive parts together to ensure they stay at the same electrical potential. The goal is to minimize voltage differences between pieces of equipment, which prevents destructive arcs during lightning strikes and reduces RF noise. 2. Power Systems and AC Safety

refers to the intentional connection of an electrical system to the earth. This provides a path for static charges, stray currents, and lightning to safely dissipate. Power, Grounding, Bonding, and Audio for Ham Ra...

Many hams mistakenly chase an "RF ground" to fix interference, but at radio frequencies, long wires have high impedance and do not act as effective grounds. is the act of connecting all conductive parts

Switch-mode power supplies (SMPS) can be a source of significant radio noise if not properly filtered. Experts recommend keeping the metal chassis of all AC-connected equipment bonded to the AC safety ground. 3. Managing RF and Interference (RFI) Power Systems and AC Safety refers to the

Every station should ideally have a single reference point for all grounds. Connecting to multiple disparate earth grounds (e.g., one for the AC service and another for the radio) creates ground loops , which can introduce hum and invite lightning surges into the shack.